#VitalStream_SOFA_EWS_Decomposition_ECMO_COVID19 #Labtech_Holter_wavelet

#VitalStream_SOFA_EWS_Decomposition_ECMO_COVID19 #Labtech_Holter_wavelet
#非侵襲_生体情報_血行動態_心拍出量_ストロークボリューム

#VitalStream_Sepsis_SCD_EWS_decomposition

#VitalStream_Sepsis_SCD_EWS_decomposition
#非侵襲_生体情報_血行動態_心拍出量_ストークボリューム

#wavelet_Labtech12leadsECG_decomposition_CaretakerMedical #SCD_EWS_proposals

#wavelet_Labtech12leadsECG_decomposition_CaretakerMedical #SCD_EWS_proposals
#周波数分析_Dr.Alfred_Haar_wavelet_Indispensable_analysis_method

#CaretakerMedical社VitalStreamの新バージョンにEWS項目追加可能

#CaretakerMedical社VitalStreamの新バージョンにEWS項目追加可能
EWS項目は、Sepsis 敗血症などの疾患で特に重要、重症かどうかの目安が数値で警告  

モバイル・スマホ・タブレット・パソコンなどに、12誘導心電図や血行動態などをオンライン・リアルタイムで表示・遠隔表示

2014年5月26日月曜日

Arterial Stiffness

Assessment of arterial stiffness in hypertension: comparison of oscillometric (Arteriograph), piezoelectronic (Complior) and tonometric (SphygmoCor) techniques. Abstract BACKGROUND Arterial stiffness, measured as aortic pulse wave velocity (PWV), and wave reflection, measured as augmentation index (AIx), are independent predictors for total and cardiovascular morbidity and mortality. The aim of this study was to compare a new device, based on oscillometric pressure curves (Arteriograph), which simultaneously measures PWV and AIx, with standard techniques for measuring PWV (Complior) and AIx (SphygmoCor) in untreated hypertensive patients. METHODS We compared PWV and AIx measured using the Arteriograph with corresponding Complior and SphygmoCor measurements in 254 untreated hypertensive patients, age 48 +/- 14 years (mean +/- SD, range 17-85 years). RESULTS Arteriograph PWV and AIx were closely related with Complior (r = 0.60, P < 0.001) and SphygmoCor (r = 0.89, P < 0.001), respectively. Using stepwise regression analysis, the independent determinants of Arteriograph PWV were age, mean arterial pressure, heart rate and sex (r(2) = 0.44, P < 0.0001) and for AIx were age, weight, mean arterial pressure, heart rate and sex (r(2) = 0.65, P < 0.0001). The bias between the different techniques was determined by age and sex for PWV and age, body weight, sex, heart rate and mean arterial pressure for AIx. Bland-Altman plots showed that although the techniques were closely related, the limits of agreement were wide. CONCLUSION Although Arteriograph values and the determinants of PWV and AIx are in close agreement with corresponding parameters obtained by Complior and SphygmoCor, respectively, the techniques are not interchangeable.